CHRocodile CLS Series

Model: CHRocodile CLS Series

 

Mô tả

CHRocodile CLS, the PRECITEC chromatic confocal line sensor offers an incredibly fast 3D measurement of 384,000 points persecond with nanometric scale resolution. Thanks to its robust and highly integrated design, CHRocodile CLS is perfectly suited for easy integration into inspection machines in the production line, including harsh industrial environments. An outstanding dynamic range and an excellent signal to noise ratio make the CHRocodile CLS the best measuring tool for all materials – including polished and highly tilted surfaces. With its unrivaled performance/price ratio, CHRocodile CLS is the best choice for ultrafast 3D inspection.

 

Characteristics

 

EFFICIENT

◆High-speed

◆Non-contact

◆Precise

VERSATILE

◆Instantaneous profile measurement

◆Inline inspection

◆Interchangeable optical probes

◆Distance and Thickness

User Friendly

◆Maintainance-free

◆Easy to integrate

◆Robust

Technical Specifications Chrocodile CLS Series

Application Distance,   thickness
Lines /second 100   – 2000, optionally 6000 Hz1)
Number   of points / line 192
Measuring   Range Depends   on optical probe
Synchronization   with external devices Trigger   input, synchronizing output, 5 encoder inputs
Interface Ethernet,   service ports: RS-422, USB
Transfer   Rate 100   Mbit (Ethernet), 9600 – 921600 Baud (RS-422), 921600 Baud (USB: virtual   comport)
Light   Source LED
Operating   Temperature +5°C   up to +50°C
Storage   Temperature -20°C   up to +70°C
Dimension   without probe (w x h x d) 391   mm x 100 mm x 114 mm
Weight 4   kg
Protection   Class IP   50 (DIN 40050/ IEC 144)
Supply   Voltage 24   +/- 10% V DC (with separate power supply 100 – 240 V AC / 50 Hz – 60 Hz)
Rated   Power 40   W
Note SDK   available. NET Framework 4 and higher compatible
Order   Number 5007994   (straight); 5007995 (90° angled); 5008859 (frequency upgrade up to 6000 Hz)

1) With reduction of measuring range

Technical Specifications of Optical Probes

Model CLS   0.2 CLS   0.5 CLS   1 CLS   2 CLS   2.3 CLS   4
Measuring   Range 200   μm 500   μm 950   μm 2000   μm 2300   μm 3900   μm
Line   length 0.96   mm ± 0.01 mm 1.43   mm ± 0,02 mm 1.91   mm ± 0.02 mm 8.3   mm ± 0.1 mm 1.53   mm ± 0.02 mm 4.78   mm ± 0.04 mm
Pitch 5   μm ± 0.05 μm 7.5   μm ± 0.08 μm 10   μm ± 0.1 μm 43.5   μm ± 0.5 μm 8   μm ± 0.08 μm 25   μm ± 0.25 μm
Working   distance1) 5.3   mm ± 0.4 mm 12   mm ± 0.4 mm 18.5   mm ± 0.5 mm 27.5   mm ± 0.5 mm 15.6   mm ± 0.5 mm 36.4   mm ± 0.6 mm
Spot   diameter 2   μm 3   μm 4   μm 17   μm 3.2   μm 10   μm
Lateral   resolution 1   μm 1.5   μm 2   μm 8.5   μm 1.6   μm 5   μm
Axial   resolution 20   nm 50   nm 80   nm 250   nm 200   nm 320   nm
Linearity   2) ± 80 nm ± 200 nm ± 300 nm ± 1 μm ± 780 nm ± 1.2 μm
Numerical   aperture 0.7 0.61 0.55 0.2 0.55 0.33
Measurement   angle to surface3) 90°+/-44° 90°+/-   38° 90°+/-33° 90°+/-11° 90°+/-33° 90°+/-20°
Thickness   measuring range4) 20   μm – 280 μm 40   μm – 700 μm 75   μm – 1.35 mm 280   μm – 2800 μm 200   μm – 3.1 mm 300   μm – 5.5 mm
Photometric   efficiency5) 7 10 14 50 2 22
Length 70.4   mm 75   mm 93.3   mm 84   mm 99   mm 120   mm
Diameter 37   mm 52   mm 54   mm 55   mm 54   mm 58   mm
Weight 190   g 240   g 430   g 200   g 390   g 510   g
Order   number 5007993 5009885 5007895 5009888 5009128 5007896

1) Bottom of optical probe to middle of measuring range

2) Perpendicular measurement on mirror at 20° C

3) Decreasing accuracy on the limits

4) Refractive index n = 1.5

5) Estimated average signal intensity in % obtained on uncoated glass at 2 kHz, LED 100 %, in the center of the measuring range.

 

Nội dung đang cập nhật
Nội dung đang cập nhật
Giới thiệu phần mềm

Bảng thông tin điều tra Sinowon

Để được giảm giá bạn hay điền vào bảng thông tin tìm hiểu sau đây, câu hỏi hoặc yêu cầu sẽ được trả lời trong một thời gian ngắn.

Cảm ơn rất nhiều vì sự hợp tác