Moving Bridge Scanning Coordinate Measuring Machine Micromea10128

Model   Micromea10128
Code#  528-181
Delivery Time  30-day
Standard  ISO10360–2
Certificate  CE

Description

Micromea10128  serials CMM combines single-point probing and analog scanning in a single high performance measuring machine also can equipped with contact and non-contact probe system. Based on the new generation of controller combines and optimizes temperature and accuracy compensation systems and advanced algorithms to support high-speed, high-accuracy analog open and closed loop scanning.

PRODUCT CHARACTERISTICS

◆ Granite fixed worktable, XZ axes are made of high performance aluminium alloy, Good temperature adaptability and faster movement speed.

◆ Granite worktable with integral “dovetail” guide in Y axis, eliminate the pitch and yaw ,also provides superior motion stability.

◆ Z axis air-balance with self-protection ,improve motion capability.

◆ Advanced synchronous belt drive system with non-slip and high stiffness, ensures high stability, lower noise.

◆ High precise, rigid, and pre-loaded air bearings on all axes, can ensure the guidance never be damped.

◆ Transmission system uses high-power  DC servo motor and new double level tape reducer to ensure rapid and accurate axes.

◆ RENISHAW tonic steel scale,Free expansion with the temperature change.

◆ Famous parts from all over the world are used in every important sub systems.

PERFORMANCE SPECIFICATIONS

Measuring Strokes(mm) Overall Dimension(mm) Machine   Weight(Kg) Max. Part Weight(Kg)
X Y Z Lx Ly Lz
1000 1200 800 1690 2370 3150 2490 1800
Accuracy is according to ISO 10360 – 2
Maximum permissible error of indication of a CMM for size   measurement (μm) Maximum permissible Probing Error (mm)
1.5 + 3L/1000 1.9
Scale   Resolution(μm): 0.1
Dynamic Performance
3D   positioning speed(mm/s) 3D acceleration(mm/s2)
530 1200

ENVIRONMENT SPECIFICATIONS

Room Required Specifications
Room Temperature 18~22°C
Temperature Gradient (in time) 1°C /h
Temperature Gradient (in time) 2°C /24h
Temperature Gradient (in the volume) 1°C /m
Humidity   Required Specifications
Relative   humidity 45-75%
Air   Supply System Required Specifications
Min.   air pressure 5bar [0.5 MPa]
Air   consumption 0.12-0.45m3/min
Electrical   requirements
Voltage 220 V ± 10%
Frequency 50/60 Hz
Max Power consumption 1500VA
Current 15 A
Allowed Maximum   Floor Vibration
Frequency Range 0 ~ 19 Hz      19~75 Hz > 75 Hz
Maximum Amplitude 0.0011 mm     0.0011~0.002 mm   0.002   mm
A good   earth ground (less than 4 W)   is required for reliable operation of the electrical controls.

Micromea10128  serials CMM combines single-point probing and analog scanning in a single high performance measuring machine also can equipped with contact and non-contact probe system. Based on the new generation of controller combines and optimizes temperature and accuracy compensation systems and advanced algorithms to support high-speed, high-accuracy analog open and closed loop scanning.

Product Characteristics

◆ Granite fixed worktable, XZ axes are made of high performance aluminium alloy, Good temperature adaptability and faster movement speed.

◆ Granite worktable with integral “dovetail” guide in Y axis, eliminate the pitch and yaw ,also provides superior motion stability.

◆ Z axis air-balance with self-protection ,improve motion capability.

◆ Advanced synchronous belt drive system with non-slip and high stiffness, ensures high stability, lower noise.

◆ High precise, rigid, and pre-loaded air bearings on all axes, can ensure the guidance never be damped.

◆ Transmission system uses high-power  DC servo motor and new double level tape reducer to ensure rapid and accurate axes.

◆ RENISHAW tonic steel scale,Free expansion with the temperature change.

◆ Famous parts from all over the world are used in every important sub systems.

Performance Specifications

Measuring Strokes(mm) Overall Dimension(mm) Machine   Weight(Kg) Max. Part Weight

(Kg)

X Y Z Lx Ly Lz
1000 1200 800 1690 2370 3150 2490 1800
Accuracy is according to ISO 10360 – 2
Maximum permissible error of indication of a CMM for size   measurement (μm) Maximum permissible Probing Error (mm)
1.5 + 3L/1000 1.9
Scale   Resolution(μm): 0.1
Dynamic Performance
3D   positioning speed(mm/s) 3D acceleration(mm/s2)
530 1200

Environment Specifications

Room Required Specifications
Room Temperature 18~22°C
Temperature Gradient (in time) 1°C /h
Temperature Gradient (in time) 2°C /24h
Temperature Gradient (in the volume) 1°C /m
Humidity   Required Specifications
Relative   humidity 45-75%
Air   Supply System Required Specifications
Min.   air pressure 5bar [0.5 MPa]
Air   consumption 0.12-0.45m3/min
Electrical   requirements
Voltage 220 V ± 10%
Frequency 50/60 Hz
Max Power consumption 1500VA
Current 15 A
Allowed Maximum   Floor Vibration
Frequency Range 0 ~ 19 Hz      19~75 Hz > 75 Hz
Maximum Amplitude 0.0011 mm     0.0011~0.002 mm   0.002   mm
A good   earth ground (less than 4 W)   is required for reliable operation of the electrical controls.
The content is being updated
Software Introduction

Sinowon Inquiry Information Table

To discount off if fill in the following inquiring information table, the question or inquiry will be replied in a short time.

Thanks a lot for the cooperation